Airwell BS 12 DCI Manuel d'utilisateur Page 86

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 98
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 85
84
Fan-
convectors
Aqu@net Cassettes
Ducted
Wall units
Air/water
chillers
Aqu@logic
Air/water
heat pump
AQU@NET
Central regulation station
AQU@NET
µBMS mini central regulation station
> Product advantages
Window contact.
Multiple configuration.
Compliant with RT2000.
The µBMS surveillance central station was designed to control operation and to monitor the temperature
of individual systems, but also average sized heating, ventilation and air conditioning systems.
It is simple to use and efficiently manages from 1 to 15 different temperature zones.
By simple programming, the user can change the set temperature values of heating and cooling modes,
select the ventilation speed for each of the areas monitored by his mini surveillance central station.
This central station makes it possible to individually monitor the following functions in each of the zones by
means of a single RS 385 communication bus (2 twisted and shielded wires):
• A programming including on/off or sleep, the time and day of the week, the operating mode,
the ventilation speed (Lo, Me, Hi, Auto), and temperature settings.
This programming selects the time ranges.
- Either individually (for each zone) for 2 time ranges.
- Or globally (for all zones) for 2 time ranges.
• A comfort (occupancy)/economy (vacant) function.
• An anti-frost function for heating mode.
• A ventilation flap control function.
Electronic controls
Type of device AWC AWN AHC AHN
Wall-mounted RCL (kit) ••••
Device mounted RCL - -
Electronic regulators
AquaNet system A = 2 Pipes
AquaNet system B = 2 Reversible Pipes (with pipe probe) (4-way valve mandatory)
AquaNet system C = 2 Pipes/2 Wires (2 electrical stages)
(1)
AquaNet system D = 2 Reversible Pipes + Additional electric power (3 Heating stages : heating valve + 2 electric stages)
(1)
(4-way valve mandatory)
AquaNet system E = 4 Pipes
(1) Second heating stage with electric battery on option, see tarif.
Regulation and communication accessories
Auxiliary board for communication via NIU bus (factory mounted)
µBMS central surveillance station (100 units and 15 zones)
Airconet@niu control board
ATTENTION: products configured per requirements. Specify the type of system desired in the order.
(A, B, C, D, E), the type of RCL control desired (built-in or remoted), the accessories.
Vue de la page 85