CONTROL SYSTEM
11.21 Jumper Settings
11.21.1 Indoor Unit Controller
0 = Open Jumper (disconnect jumper).
1 = Close Jumper (connect jumper).
Self test Jumper – J1
OPERATION J1
SELF-TEST 1
NORMAL 0
Compensation Jumper – J2
Model J2 (Default) Compensation
Wall Mounted 0 Activated
Floor/Ceiling 1 Deactivated
Ducted/cassette 1 Activated
Family selection Jumper – J3, J4 and J5
Family J5 J4 J3
Reserved
Reserved
Reserved
Wall Mounted (WNG/FLO)
Floor/Ceiling (PXD)
Reserved
Ducted (LS)
Cassette (K)
0 0 0
0 0 1
0 1 0
0 1 1
1 0 0
1 0 1
1 1 0
1 1 1
Model selection Jumper – J6, J7
Model J7 J6
9000 Btu/hr
12000 Btu/hr
18000 Btu/hr
24000 Btu/hr
0 0
0 1
1 0
1 1
J8- Clock/Power Shedding
Operation J8
Clock 0
Power Shedding 1
J9 – IFAN Cycling Disabling
Display Mode
(wall mounted units only)
J9
LCD 0
LED 1