Airwell GC 12 DCI Manuel de service Page 12

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 171
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 11
2-6
PRODUCT DATA SHEET
SM HADDCI 1-A.2 GB
2.6 HAD018 / GC 18 DCI
Model Indoor Unit
HAD018 DCI
Model Outdoor Unit
GC 18 R410A
Installation Method of Pipe Flared
Characteristics Units Cooling Heating
Capacity
(4)
Btu/hr 17060(5120-20470) 20470(5120-25930)
kW 5.00(1.50-6.00) 6.00(1.50-7.60)
Power input
(4)
kW 1.46(0.50-2.00) 1.66(0.45-2.20)
EER (Cooling) or COP(Heating)
(4)
W/W 3.42 3.61
Energy efficiency class A A
Power supply
V 220-240
Ph Single
Hz 50
Rated current A 6.5 7.4
Power factor 0.97 0.97
Prated (IDU) W 56
Prated (IDU+ODU) W 2200
Starting current A 10.5
Circuit breaker rating A 20
INDOOR
Fan type & quantity Crossflow x 1
Fan speeds H/M/L RPM 1200/1050/900
Air flow
(1)
H/M/L m3/hr 850/700/550
External static pressure Min Pa 0
Sound power level
(2)
H/M/L dB(A) 58/54/50
Sound pressure level
(3)
H/M/L dB(A) 44/39/34
Moisture removal l/hr 2
Condenstate drain tube I.D mm 16
Dimensions WxHxD mm 1060x295x221
Net Weight kg 15
Package dimensions WxHxD mm 1125x360x295
Packaged weight kg 18
Units per pallet units 16
Stacking height units 8 levels
OUTDOOR
Refrigerant control EEV
Compressor type,model Scroll,Panasonic 5CS130XCC03
Fan type & quantity Propeller(direct) x 1
Fan speeds H RPM 920
Air flow H
m
3
/hr
2160
Sound power level H dB(A) 63
Sound pressure level
(3)
H dB(A) 53
Dimensions WxHxD mm 795x610x290
Net Weight kg 39
Package dimensions WxHxD mm 945x655x395
Packaged weight kg 43
Units per pallet Units 9
Stacking height units 3 levels
Refrigerant type R410A
Standard charge kg(7.5m) 1.50kg
Additional charge No need
Connections
between units
Liquid line In.(mm) 1/4"(6.35)
Suction line In.(mm) 1/2"(12.7)
Max.tubing length m. 30
Max.height difference m. 10
Operation control type Remote control
Heating elements (Option) kW
Others
(1) Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN 14511.
(2) Airflow in ducted units; at nominal external static pressure.
(3) Sound power in ducted units is measured at air discharge.
(4) Sound pressure level measured at 1 meter distance from unit.