2-3
PRODUCT DATA SHEET
SM HADDCI 1-A.2 GB
2.3 HAD009 / GCD009 DCI
Model Indoor Unit HAD009 DCI
Model Outdoor Unit GCD 009 R410A
Installation Method of Pipe Flared
Characteristics Units Cooling Heating
Capacity
(4)
Btu/hr 8530(2730-10240) 8530(3410-10920)
kW 2.5(0.8-3.0) 2.5(1.0-3.2)
Power input
(4)
kW 0.78(0.30-1.00) 0.69(0.37-0.90)
EER (Cooling) or COP(Heating)
(4)
W/W 3.21 3.61
Energy efficiency class A A
Power supply
V 220-240
Ph 1
Hz 50
Rated current A 3.5 3.1
Power factor 0.97 0.97
Prated (IDU) W 25
Prated (IDU+ODU) W 1400
Starting current A 10.5
Circuit breaker rating A 10
INDOOR
Fan type & quantity Crossflow x 1
Fan speeds H/M/L RPM 1150/1000/800
Air flow
(1)
H/M/L m3/hr 420/350/270
External static pressure Min Pa 0
Sound power level
(2)
H/M/L dB(A) 54
Sound pressure level
(3)
H/M/L dB(A) 40/35/29
Moisture removal l/hr 1.0
Condenstate drain tube I.D mm 16
Dimensions WxHxD mm 680 x250 X188
Net Weight kg 7
Package dimensions WxHxD mm 740x310x248
Packaged weight kg 10
Units per pallet units 32
Stacking height units 8
OUTDOOR
Refrigerant control Capillary
Compressor type,model Rotary, Toshiba, DA89X1C-20FZ3
Fan type & quantity Propeller(direct) x 1
Fan speeds H RPM 830
Air flow H m3/hr 1460
Sound power level H dB(A) 65
Sound pressure level
(3)
H dB(A) 55
Dimensions WxHxD mm 760x545x245
Net Weight kg 31
Package dimensions WxHxD mm 880x610x310
Packaged weight kg 33
Units per pallet Units 12 units per pallet
Stacking height units 3 levels
Refrigerant type R410A
Scharg kg(7.5m) 0.7
Additional charge L10m:+0g 10L 15m:+200g
Connections between units
Liquid line In.(mm) 1/4"(6.35)
Suction line In.(mm) 3/8"(9.53)
Max.tubing
length
m. Max. 15
Max.height
difference
m. Max. 10
Operation control type Remote control
Heating elements (Option) kW
Others
(1) Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN 14511.
(2) Airflow in ducted units; at nominal external static pressure.
(3) Sound power in ducted units is measured at air discharge.
(4) Sound pressure level measured at 1 meter distance from unit.