Airwell BS 12 DCI Manuel de service

Naviguer en ligne ou télécharger Manuel de service pour Climatiseurs à système divisé Airwell BS 12 DCI. Airwell BS 12 DCI Service manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 103
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Multi Split Trio Quattro Z DCI
Indoor Units Outdoor Units
PNX009
YAZ3 24 DCI
YAZ4 30 DCI
PNX012
PNX018
CK009
CK012
CK018
SX009
SX012
SX018
DLF009
DLF012
DLF018
XLF009
XLF012
DLS018
PRIME009
PRIME012
PRIME018
HAD009
HAD012
JANUARY – 2010
REFRIGERANT
R410A HEAT PUMP
SM YAZDCI 1-A.1 GB
Vue de la page 0
1 2 3 4 5 6 ... 102 103

Résumé du contenu

Page 1 - R410A HEAT PUMP

Multi Split Trio Quattro Z DCIIndoor Units Outdoor UnitsPNX009YAZ3 24 DCIYAZ4 30 DCIPNX012PNX018CK009CK012CK018SX009SX012SX018DLF009DLF012DLF018XLF009

Page 2 - LIST OF EFFECTIVE PAGES

2-4PRODUCT DATA SHEETSM YAZDCI 1-A.1 GB2.3.3 PNX018 DCI SpecificationsModel Indoor Unit PNX018 DCIInstallation Method of Pipe FlaredPower supply V/Ph

Page 3 - Table of Contents

13-2EXPLODED VIEWS AND SPARE PARTS LISTSSM YAZDCI 1-A.1 GB13.2 Outdoor Unit: YAZ3 24 DCIItem Seq Item Description Quantity1 465100000 Grill/ DCI Trio

Page 4 - 1. INTRODUCTION

13-3EXPLODED VIEWS AND SPARE PARTS LISTSSM YAZDCI 1-A.1 GB13.3 Outdoor Unit: YAZ4 30 DCINo. P/N Part Name Quantity 1 4522604 Outlet Grid 12 452365

Page 5 - INTRODUCTION

13-4EXPLODED VIEWS AND SPARE PARTS LISTSSM YAZDCI 1-A.1 GB13.4 Outdoor Unit: YAZ4 30 DCIItem Seq Component Item Description Quantity1 465100000 Grill

Page 6 - 1.6 Indoor Unit combinations

14-1APPENDIX ASM YAZDCI 1-A.1 GBAPPENDIX AINSTALLATION AND OPERATION MANUAL► INSTALLATION MANUAL YAZ3 24, YAZ4 30 DCI

Page 7 - 2. PRODUCT DATA SHEET

2-5PRODUCT DATA SHEETSM YAZDCI 1-A.1 GB2.3.5 CK012 DCI SpecificationsModel Indoor Unit CK 012 DCIInstallation Method of Pipe FlaredPower supply V/Ph/

Page 8

2-6PRODUCT DATA SHEETSM YAZDCI 1-A.1 GB2.3.7 SX009 DCI Specifications Model Indoor Unit SX009 DCI Installation Method of Pipe FlaredPower supply V/Ph

Page 9 - 2.3 Indoor Units Data

2-7PRODUCT DATA SHEETSM YAZDCI 1-A.1 GB2.3.9 SX018 DCI SpecificationsModel Indoor Unit SX018 DCI Installation Method of Pipe FlaredPower supply V/Ph/

Page 10 - SM YAZDCI 1-A.1 GB

2-8PRODUCT DATA SHEETSM YAZDCI 1-A.1 GB2.3.11 DLF012 DCI Specifications Model Indoor Unit DLF012 DCI Installation Method of Pipe DUCTEDPower supply V

Page 11

2-9PRODUCT DATA SHEETSM YAZDCI 1-A.1 GB2.3.13 XLF009 DCI SpecificationsModel Indoor Unit XLF009 DCIInstallation Method of Pipe FlaredPower supply V/P

Page 12

2-10PRODUCT DATA SHEETSM YAZDCI 1-A.1 GB2.3.15 DLS018 DCI Specifications Model Indoor Unit DLS018 DCIInstallation Method of Pipe FlaredPower supply V

Page 13

2-11PRODUCT DATA SHEETSM YAZDCI 1-A.1 GB2.3.17 PRIME012 DCI SpecificationsModel Indoor Unit PRIME012 DCIInstallation Method of Pipe FlaredPower suppl

Page 14

2-12PRODUCT DATA SHEETSM YAZDCI 1-A.1 GB2.3.19 HAD009 DCI SpecificationsModel Indoor Unit HAD009 DCIInstallation Method of Pipe FlaredPower supply V/

Page 15

3-1RATING CONDITIONS SM YAZDCI 1-A.1 GB3. RATING CONDITIONSStandard conditions in accordance with ISO 5151, ISO 13253

Page 16

ALIST OF EFFECTIVE PAGESSM YAZDCI 1-A.1 GBLIST OF EFFECTIVE PAGESNote: Changes in the pages are indicated by a “Revision#” in the footer of each effe

Page 17

4-1OUTLINE DIMENSIONSSM YAZDCI 1-A.1 GB4. OUTLINE DIMENSIONS4.1 Indoor Unit: PNX009 / PNX012 DCI4.2 Indoor Unit: PNX018 DCI1060221295AIR INTAKEAIR I

Page 18

4-2OUTLINE DIMENSIONS SM YAZDCI 1-A.1 GB4.3 Indoor Unit: CK009, CK012, CK018 DCI4.4 Indoor Unit: SX009, SX012 SX018 DCIUnit

Page 19 - 3. RATING CONDITIONS

4-3OUTLINE DIMENSIONSSM YAZDCI 1-A.1 GB4.5 Indoor Unit: DLF009, DLF012, DLF018 DCI4.6 Indoor Unit: XLF009, XLF012 DCIAC565B629 (640 With air filter)

Page 20 - 4. OUTLINE DIMENSIONS

4-4OUTLINE DIMENSIONS SM YAZDCI 1-A.1 GB4.7 Indoor Unit: DLS018 DCIModel A B C D E F G H I J K LDLF018 DCI 790 653 749 758 797 256 195 702 599

Page 21 - OUTLINE DIMENSIONS

4-5OUTLINE DIMENSIONSSM YAZDCI 1-A.1 GB4.9 Indoor Unit: PRIME012 DCI4.10 Indoor Units: PRIME018 DCI900295AIR INTAKEAIR INTAKEAIR OUTLET205MOUNTING T

Page 22

4-6OUTLINE DIMENSIONS SM YAZDCI 1-A.1 GB4.11 Indoor Unit: HAD009 DCI4.12 Indoor Units: HAD012 DCI

Page 23 - 4.7 Indoor Unit: DLS018 DCI

4-7OUTLINE DIMENSIONSSM YAZDCI 1-A.1 GB37848527865950340AIR INTAKEAIR OUTLET4.13 Outdoor Units: YAZ3 24, YAZ4 30 DCI

Page 24

5-1PERFORMANCE DATASM YAZDCI 1-A.1 GB5. PERFORMANCE DATA5.1 Outdoor Unit YAZ3 24 DCI Combinations (Based on PNX)5.1.1 CoolingModelCooling Capacity [

Page 25 - 4.11 Indoor Unit: HAD009 DCI

5-2PERFORMANCE DATA SM YAZDCI 1-A.1 GB5.1.2 HeatingModelHeaing Capacity [KW] Power Consumption[W] COPNominal Energy EfficiencyClassA B D Nom.

Page 26

5-3PERFORMANCE DATASM YAZDCI 1-A.1 GB5.2 Outdoor Unit YAZ4 30 DCI Combinations (Based on PNX)5.2.1 CoolingModelCooling Capacity [KW] Power Consumptio

Page 27 - 5. PERFORMANCE DATA

iTABLE OF CONTENTSSM YAZDCI 1-A.1 GBTable of Contents1. INTRODUCTION ...

Page 28 - 5.1.2 Heating

5-4PERFORMANCE DATA SM YAZDCI 1-A.1 GB5.2.2 HeatingModelHeating Capacity [KW] Power Consumption[W] COPNominal Energy EfficiencyClassA B C D No

Page 29 - 5.2.1 Cooling

5-5PERFORMANCE DATASM YAZDCI 1-A.1 GB5.3 PNX009 DCI5.3.1 Cooling Capacity Factors - Unit A,B,C or D230[V] : Indoor Fan at High Speed. ID COIL ENTE

Page 30 - 5.2.2 Heating

5-6PERFORMANCE DATA SM YAZDCI 1-A.1 GB5.3.3 Heating Capacity Factors - Unit A,B,C or D230[V] : Indoor Fan at High Speed. ID COIL ENTERING A

Page 31

5-7PERFORMANCE DATASM YAZDCI 1-A.1 GB5.4 PNX012 DCI5.4.1 Cooling Capacity Factors - Unit A,B,C or D230[V] : Indoor Fan at High Speed. ID COIL ENTERIN

Page 32

5-8PERFORMANCE DATA SM YAZDCI 1-A.1 GB5.4.3 Heating Capacity Factors - Unit A,B,C or D230[V] : Indoor Fan at High Speed. ID COIL ENTERING A

Page 33

5-9PERFORMANCE DATASM YAZDCI 1-A.1 GB5.5 PNX018 DCI5.5.1 Cooling Capacity Factors - Unit D230[V] : Indoor Fan at High Speed. ID COIL ENTERING AIR

Page 34

5-10PERFORMANCE DATA SM YAZDCI 1-A.1 GB5.5.3 Heating Capacity Factors - Unit D230[V] : Indoor Fan at High Speed. ID COIL ENTERING AIR DB TE

Page 35

5-11PERFORMANCE DATASM YAZDCI 1-A.1 GB5.6 CK009 DCI 5.6.1 Cooling Capacity Factors - Unit A,B,C or D230[V] : Indoor Fan at High Speed. ID COIL ENTERI

Page 36

5-12PERFORMANCE DATA SM YAZDCI 1-A.1 GB5.6.3 Heating Capacity Factors - Unit A,B,C or D 230[V] : Indoor Fan at High Speed.ID COIL ENTERING A

Page 37

5-13PERFORMANCE DATASM YAZDCI 1-A.1 GB5.7 CK012 DCI 5.7.1 Cooling Capacity Factors - Run Mode (Unit A,B,C or D) 230[V] : Indoor Fan at High Speed. I

Page 38

1-1INTRODUCTIONSM YAZDCI 1-A.1 GB1. INTRODUCTION1.1 GeneralThe Trio/Quattro Z DCI Multi series is a full line multi-tubing system with 3 to 4 connecte

Page 39

5-14PERFORMANCE DATA SM YAZDCI 1-A.1 GB5.7.3 Heating Capacity Factors - Unit A,B,C or D 230[V] : Indoor Fan at High Speed. ID COIL ENTERIN

Page 40

5-15PERFORMANCE DATASM YAZDCI 1-A.1 GB5.8 CK018 DCI 5.8.1 Cooling Capacity Factor - Unit D 230[V] : Indoor Fan at High Speed. ID COIL ENTERING AIR D

Page 41 - 5.8 CK018 DCI

5-16PERFORMANCE DATA SM YAZDCI 1-A.1 GB5.8.3 Heating Capacity Factor - Unit D 230[V] : Indoor Fan at High Speed.ID COIL ENTERING AIR DB TEMP

Page 42

5-17PERFORMANCE DATASM YAZDCI 1-A.1 GBTubing Length Capacity Ratio - Cooling (1 Unit)0.760.810.860.910.961.011.060 5 10 15 20 25 30Tubing Length [m]Ca

Page 43 - 5.9.2 Heating

5-18PERFORMANCE DATA SM YAZDCI 1-A.1 GB5.10 Model Correction Factors (FM)ModelCapacity Power inputCooling Heating Cooling HeatingPNX DCI1.00

Page 44 - 15.11 Calculation Example

6-1PRESSURE CURVESSM YAZDCI 1-A.1 GB6. PRESSURE CURVES6.1 Model: YAZ3 24 DCI6.1.1 Cooling – Technician Mode Discharge Pressure - Cooling (Technici

Page 45 - 6. PRESSURE CURVES

6-2PRESSURE CURVESSM YAZDCI 1-A.1 GB6.1.2 Heating – Technician Mode Discharge Pressure - Heating (Technician Mode)(WNG25+25+25 ; 5m each)10.0012.00

Page 46 - (WNG25+25+25 ; 5m each)

6-3PRESSURE CURVESSM YAZDCI 1-A.1 GB6.1.3 Tubing Length correction Factor6.1.4 Outdoor Unit Code correction Factor (FC)ODU CodeCooling HeatingSuctio

Page 47 - Heating Pd

6-4PRESSURE CURVESSM YAZDCI 1-A.1 GB6.1.5 Unit Model correction Factor (Fm)ModelCooling Heating SuctionPressure DischargePressure SuctionPressure Dis

Page 48 - PRESSURE CURVES

6-5PRESSURE CURVESSM YAZDCI 1-A.1 GB6.2 Model: YAZ4 30 DCI6.2.1 Cooling – Technician ModeDischarge Pressure - Cooling (Technician Mode)(WNG25+25+25+

Page 49 - 6.2 Model: YAZ4 30 DCI

1-2INTRODUCTIONSM YAZDCI 1-A.1 GB1.5 Matching Table R410AINDOOR UNITSOUTDOOR UNITSTrio YAZ3 24 DCI Quattro YAZ4 30 DCIPNX009√√PNX012√√PNX018√√CK009√√C

Page 50

6-6PRESSURE CURVESSM YAZDCI 1-A.1 GB6.2.2 Heating – Technician Mode Discharge Pressure - Heating (Technician Mode) (WNG25+25+25+25 ; 5m each)10.0012

Page 51

6-7PRESSURE CURVESSM YAZDCI 1-A.1 GB6.2.3 Tubing Length correction Factor (FT)6.2.4 Unit Code correction Factor (FC)ODU CodeCooling Heating SuctionP

Page 52

6-8PRESSURE CURVESSM YAZDCI 1-A.1 GB6.2.5 Unit Model correction Factor (Fm)ModelCooling HeatingSuction PressureDischarge PressureSuction PressureDisc

Page 53 - 6.3 Calculation Example

6-9PRESSURE CURVESSM YAZDCI 1-A.1 GB6.3 Calculation ExampleOutdoor UnitYAZ4 30 DCIIndoor CombinationPNX009+PNX012+CK012+PNX018Operation ModeCooling Mo

Page 54 - 7. ELECTRICAL DATA

7-1ELECTRICAL DATASM YAZDCI 1-A.1 GB7. ELECTRICAL DATA7.1 Trio 72 Z, Quattro 80 Z DCIPower Supply 1 PH, 220-240 VAC, 50HzConnected to OutdoorMaximum

Page 55

8-1WIRING DIAGRAMS & ELECTRICAL CONNECTIONSSM YAZDCI 1-A.1 GB8. WIRING DIAGRAMS & ELECTRICAL CONNECTIONS8.1 Outdoor Units: YAZ3 24, YAZ4 30

Page 56 - 9. REFRIGERATION DIAGRAMS

9-1REFRIGERATION DIAGRAMSSM YAZDCI 1-A.1 GB9. REFRIGERATION DIAGRAMS9.1 YAZ3 24 DCI, YAZ4 30 DCI Outdoor Unit Refrigerant System DiagramOMT

Page 57 - ¼” ⅜”½”⅝”¾”

10-1TUBING CONNECTIONSSM YAZDCI 1-A.1 GB10. TUBING CONNECTIONS TUBE (Inch)TORQUE (Nm)¼” ⅜”½”⅝”¾”Flare Nuts 11-13 40-45 60-65 70-75 80-85Valve Cap

Page 58 - 11. CONTROL SYSTEM

11-1CONTROL SYSTEMSM YAZDCI 1-A.1 GB11. CONTROL SYSTEM11.1 AbbreviationsAbbreviation DefinitionA/C Air Condition BMS Building Management SystemPWR Sy

Page 59 - 11.2 Product Overview

11-2CONTROL SYSTEM SM YAZDCI 1-A.1 GB11.2 Product Overview11.2.1 Block Diagram11.2.2 CompressorDC brush less and sensor less 2.5/3 horsepower m

Page 60 - 11.3 General Operating Rules

1-3INTRODUCTIONSM YAZDCI 1-A.1 GB1.6 Indoor Unit combinationsTrio QuattroUnit A Unit B Unit D Code Sum Unit A Unit B Unit C Unit D Code Sum009 009 00

Page 61 - 111. CONTROL SYSTEM

11-3CONTROL SYSTEMSM YAZDCI 1-A.1 GB11.2.7 Dry ContactsDry contacts are used to interface the system with an external building management system (BMS)

Page 62 - CONTROL SYSTEM

11-4CONTROL SYSTEM SM YAZDCI 1-A.1 GB111. CONTROL SYSTEM11.3.1.1 IDU’s Initializatio11.3.1.1.1 Capacity Codes SettingThe capacity groups of th

Page 63 - 11.4 Indoor Unit Control

11-5CONTROL SYSTEMSM YAZDCI 1-A.1 GBThe following combinations show the allowed and not allowed capacity group:ODU Model Communication channelIs it al

Page 64 - ICTST ICTVL ICTL ICTH ICTT

11-6CONTROL SYSTEM SM YAZDCI 1-A.1 GB11.3.3 Temperature Measurements11.3.3.1 Thermistor failures definitionThermistor Type a – Disconnected Ty

Page 65

11-7CONTROL SYSTEMSM YAZDCI 1-A.1 GB11.4.3 Heat ModeNLOAD is calculated according to the difference between actual room temperature and user set point

Page 66

11-8CONTROL SYSTEM SM YAZDCI 1-A.1 GB11.4.6 Indoor Units Operation when Indoor Unit Mode is Different than Outdoor Unit Mode Open louvers acc

Page 67 - 11.5 Run Mode

11-9CONTROL SYSTEMSM YAZDCI 1-A.1 GB11.4.12.2 LCD DisplaySTBY Cool Heat Auto Fan DryOFF SPT SPT SPT SPT SPTOFF ON ON ON ON ONOFF OFF OFF OFF OFF OFF

Page 68

11-10CONTROL SYSTEM SM YAZDCI 1-A.1 GB11.5 Run ModeRun mode is the default operation mode of the system. This is the standard operation mode th

Page 69

11-11CONTROL SYSTEMSM YAZDCI 1-A.1 GB11.5.2.2 Compressor Speed calculationDuring normal operation (excluding protections), the compressor speed is li

Page 70 - HEAT 50 to 480 50 to 120

11-12CONTROL SYSTEM SM YAZDCI 1-A.1 GB11.5.2.4 Outdoor Unit NLOAD calculationIndoor Unit2Indoor Unit3Indoor Unit4OutdoorControllerNLOAD2Code2N

Page 71

2-1PRODUCT DATA SHEETSM YAZDCI 1-A.1 GB2. PRODUCT DATA SHEET2.1 Outdoor Trio YAZ3 24 DCI Specifications.Model Indoor Unit Model Outdoor UnitDCI Tri

Page 72

11-13CONTROL SYSTEMSM YAZDCI 1-A.1 GB11.5.3 EEV Control11.5.3.1 Operation RangeThe EEV operation range is defined according to the operation mode as f

Page 73 - Normal 90 72 3050 2300

11-14CONTROL SYSTEM SM YAZDCI 1-A.1 GB11.5.3.6 Balance timeDuring the first 5 minutes after SB the correction is not calculated. After that the

Page 74

11-15CONTROL SYSTEMSM YAZDCI 1-A.1 GB11.5.7 Thermodynamic Protections11.5.7.1 Protection level definitionFive protection levels are defined:Normal –

Page 75 - 11.6 Installation Test Mode

11-16CONTROL SYSTEM SM YAZDCI 1-A.1 GBThe following table summarizes the basic levels of each protection. ProtectionlevelCompressorOverheat (CT

Page 76

11-17CONTROL SYSTEMSM YAZDCI 1-A.1 GB11.5.9 Condensate Water over Flow ProtectionP1 P2 P3 P4Level Connector Top ViewEach of the pins P1, P2, P3 can h

Page 77

11-18CONTROL SYSTEM SM YAZDCI 1-A.1 GBANY0ONNLOADPUMPOFFONOPERLEDOFFOverflowWater LevelNormalBLINKNLOAD isforced to 08 min 8 minOverflow whenun

Page 78 - Term Possible reasons

11-19CONTROL SYSTEMSM YAZDCI 1-A.1 GB11.6.4 Installation test menuInstallation Test (it)╚════════════╦══ Number of IDUs (nID)

Page 79

11-20CONTROL SYSTEM SM YAZDCI 1-A.1 GBYou can scroll the menu to observe:6. Observe the matrix resulta. Guide for problem correction.b. For fix

Page 80 - 11.7 Technician Test Mode

11-21CONTROL SYSTEMSM YAZDCI 1-A.1 GBPresent for 2 sec Present for 2 Sec. Interpretationx--: Cz‘x’ is the wire name (1,2,3,4)‘z’ is the communication

Page 81 - 11.8 User Interface

11-22CONTROL SYSTEM SM YAZDCI 1-A.1 GBExamples:#Problem Correction (Crt) Problem Correction (Crt)1,2HMI DisplayTechnician Interpretation2--:Cb

Page 82 - 11.8.3 Main Menu

2-2PRODUCT DATA SHEETSM YAZDCI 1-A.1 GB2.2 Outdoor QUATTRO YAZ4 30 DCI Specifications. Model Indoor Unit Model Outdoor UnitDCI Quattro YAZ4 30 R410

Page 83

11-23CONTROL SYSTEMSM YAZDCI 1-A.1 GBStored Matrix Type[Rows, Column]How to present?2 x 2Repeat: r1(keep 2 sec) X1Y1 (keep 2 sec)Repeat: r2 (keep 2 s

Page 84

11-24CONTROL SYSTEM SM YAZDCI 1-A.1 GB11.7.2 Technician mode procedureAll the connected indoor units will enter technician test at high indoor

Page 85 - 11.10 System Parameters

11-25CONTROL SYSTEMSM YAZDCI 1-A.1 GB11.8.3 Main Menu11.8.3.1 MenusDefault (refer to the note)Technician Test (tt)╚════════════╦══Technician Test Cool

Page 86

11-26CONTROL SYSTEM SM YAZDCI 1-A.1 GBExiting ‘Status’ menu and its sub-menus back to the main menu is done by either pressing 4. escape or aft

Page 87

11-27CONTROL SYSTEMSM YAZDCI 1-A.1 GB11.8.3.2 Status (Sub Menu)IDU (IDU)╚════════ICT (ICT)╚════════════╦══ ICT1 (A)╠══ ICT2 (B)╠══ ICT3 (C)╚══ ICT4 (

Page 88 - Fix RPM Motor

11-28CONTROL SYSTEM SM YAZDCI 1-A.1 GBThe current is the AC current of the unit.o The models A, b, C, and d will be presented -A-, -b-, -c-, an

Page 89 - 12. TROUBLESHOOTING

11-29CONTROL SYSTEMSM YAZDCI 1-A.1 GB# Name Default Value Units33. ICTOH3 52 °C34. ICTOH4 55 °C35. ICTOH5 58 °C36. ICTOH6 61 °C37. EEVLearning 138. EE

Page 90 - TROUBLESHOOTING

11-30CONTROL SYSTEM SM YAZDCI 1-A.1 GB# NameP(DCI80)Unit40. EEV_Active_H_SC 10 °C41. EEV_Active_H_SC_Crct 1 °C42.EnableExceedCond 043. OVRPWR1

Page 91 - 12.3 Diagnostics

11-31CONTROL SYSTEMSM YAZDCI 1-A.1 GB11.10.3.2 Model Depended Parameters:Parameter nameWall Mounted Models Floor/Ceiling Models Cassette Models Ducte

Page 92

12-1TROUBLESHOOTINGSM YAZDCI 1-A.1 GB12. TROUBLESHOOTINGWARNING!!!When Power Up – the whole outdoor unit controller, including the wiring, is under HI

Page 93

2-3PRODUCT DATA SHEETSM YAZDCI 1-A.1 GB2.3 Indoor Units Data2.3.1 PNX009 DCI SpecificationsModel Indoor Unit PNX009 DCIInstallation Method of Pipe F

Page 94 - 12.3.3 DMSMP diagnostics

12-2TROUBLESHOOTING SM YAZDCI 1-A.1 GBNo SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION9.Outdoor unit display board and leds are offNo power supplyCh

Page 95 - No Fault Name 54321

12-3TROUBLESHOOTINGSM YAZDCI 1-A.1 GB12.2 Checking the refrigeration systemChecking system pressures and other thermodynamic measures should be done

Page 96

12-4TROUBLESHOOTING SM YAZDCI 1-A.1 GB11.3.2 Outdoor unit diagnostics and corrective actionsNo Fault Name Fault Description Corrective Action1

Page 97

12-5TROUBLESHOOTINGSM YAZDCI 1-A.1 GBNo Fault Name Fault Description Corrective Action20 Heat sink Over HeatingCompressor stopped due to heatsink prot

Page 98 - 12.5.2 Charged Capacitors

12-6TROUBLESHOOTING SM YAZDCI 1-A.1 GB12.3.3 DMSMP diagnosticsThe DMSMP system has 4 IDU LEDs, 1 ODU LED, and 1 Power LED.Each communication ch

Page 99

12-7TROUBLESHOOTINGSM YAZDCI 1-A.1 GB12.3.4 Fault Code for Indoor unitPressing Mode button for long will activate diagnostic mode by the acknowledgme

Page 100

12-8TROUBLESHOOTING SM YAZDCI 1-A.1 GB12.3.5 Indoor unit diagnostics and corrective actionsNo. Fault Probable Cause Corrective Action1-4 Senso

Page 101

12-9TROUBLESHOOTINGSM YAZDCI 1-A.1 GBChange to Stand-by or Power OFF and re-start - If the fault is still active - replace controller.12.4.5 aaChecki

Page 102

12-10TROUBLESHOOTING SM YAZDCI 1-A.1 GBCorrection :The fundamental concept is to make the system less susceptible to noise (insulate for noise

Page 103 - APPENDIX A

13-1EXPLODED VIEWS AND SPARE PARTS LISTSSM YAZDCI 1-A.1 GB13. EXPLODED VIEWS AND SPARE PARTS LISTS13.1 Outdoor Unit: YAZ3 24 DCI

Commentaires sur ces manuels

Pas de commentaire